Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.742
Filtrar
1.
Arch Ital Urol Androl ; 96(1): 12186, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38572723

RESUMO

OBJECTIVE: Various factors, such as obstructive azoospermia, cause infertility in men. Biochemical examination of ejaculate, especially measurement of fructose, can be an additional investigation that can be used for this diagnosis in reproductive health. Examination of fructose is carried out after routine ejaculate analysis, resulting in prolonging the examination time so that it will affect the measurement of fructose level in the ejaculate and the accuracy of the diagnosis. This study aims to determine the best timing and procedure for measurement of fructose using a semiautomatic method. METHODS: This research is an analytic observational study conducted at Dr. Soetomo General Hospital, Surabaya. A total of 13 ejaculate samples from infertile male patients who met the inclusion criteria were evaluated. Each ejaculate was divided into eight aliquots that were examined for fructose using a semiautomated method after different intervals of time and centrifugation modalities. RESULTS: This study showed a significant difference in fructose levels when aliquots were centrifuged and examined immediately or after different interval of time (p=0.036). In addition, aliquots left standing for more than 60 minutes (p=0.012) and 120 minutes (p<0.001) before centrifugation, showed significantly lower levels compared to aliquots that were centrifuged and then immediately examined. CONCLUSIONS: We suggest that measuring fructose immediately after centrifugation is more reliable than measuring fructose left standing before or after centrifugation. Leaving the ejaculate standing will reduce the fructose level so that it does not resemble its real level.


Assuntos
Azoospermia , Infertilidade Masculina , Humanos , Masculino , Frutose , Infertilidade Masculina/diagnóstico , Infertilidade Masculina/etiologia , Centrifugação , Espermatozoides
2.
Biomed Microdevices ; 26(2): 22, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592604

RESUMO

We report a centrifugal microfluidic device that automatically performs sample preparation under steady-state rotation for clinical applications using mass spectrometry. The autonomous microfluidic device was designed for the control of liquid operation on centrifugal hydrokinetics (CLOCK) paradigm. The reported device was highly stable, with less than 7% variation with respect to the time of each unit operation (sample extraction, mixing, and supernatant extraction) in the preparation process. An agitation mechanism with bubbling was used to mix the sample and organic solvent in this device. We confirmed that the device effectively removed the protein aggregates from the sample, and the performance was comparable to those of conventional manual sample preparation procedures that use high-speed centrifugation. In addition, probe electrospray ionization mass spectrometry (PESI-MS) was performed to compare the device-treated and manually treated samples. The obtained PESI-MS spectra were analyzed by partial least squares discriminant analysis, and the preparation capability of the device was found to be equivalent to that of the conventional method.


Assuntos
Microfluídica , Espectrometria de Massas por Ionização por Electrospray , Centrifugação , Dispositivos Lab-On-A-Chip , Rotação
3.
Clin Oral Investig ; 28(4): 225, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38514526

RESUMO

OBJECTIVE: To investigate how delayed blood centrifugation affects the composition of the resultant platelet rich fibrin membrane (PRF, a concentrated growth factor preparation) and its biological effects towards gingival fibroblasts. MATERIALS AND METHODS: Blood samples were collected from 18 healthy individuals and centrifuged immediately (T-0), or after a 1-6-minute delay (T-1-6, respectively), to generate PRF. Each PRF membrane was weighed. T-0 and T-6 membranes were incubated for 48 h in cell culture medium at 37 °C to create PRF "releasates" (soluble factors released from the PRF). Human gingival fibroblasts were incubated for 48 h with or without the releasates, followed by RNA isolation and real-time polymerase chain reaction to measure expression of select genes associated with granulation tissue formation, angiogenesis and wound contraction. Additional T-0 and T-6 membranes were used for visualization of leucocyte nuclei and platelets by immunostaining. RESULTS: Immediate centrifugation (T-0) resulted in the largest membranes, T-6 membranes being on average 29% smaller. Leucocytes and platelets were significantly more abundant in T-0 than in T-6 samples. Majority of the fibroblast genes studied were consistently either upregulated or downregulated by the T-0 PRF releasates. However, centrifugation after a 6-minute delay significantly weakened the fibroblast responses. CONCLUSIONS: Delayed centrifugation resulted in smaller PRF membranes with fewer leucocytes and platelets and also significantly reduced on the expression of a set of healing-related gingival fibroblast genes. CLINICAL RELEVANCE: The higher expression of wound healing-related genes in gingival fibroblasts by the immediately-centrifuged PRF membranes may increase their biological properties in clinical use.


Assuntos
Fibrina Rica em Plaquetas , Humanos , Plaquetas , Cicatrização , Leucócitos , Centrifugação/métodos
4.
Scand J Clin Lab Invest ; 84(1): 62-67, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38451167

RESUMO

Glucose measurement plays a central role in the diagnosis of gestational diabetes mellitus (GDM). Because of earlier reports of overestimation of glucose in the widely used tubes containing granulated glycolysis inhibitor, the study assessed the performance of fast-clotting serum tubes as an alternative sample for the measurement of glucose. Glucose concentration in fast-clotting serum was compared to lithium-heparin plasma placed in an ice-water slurry after sample collection and glucose stability at room-temperature was studied. Blood samples from 30 volunteers were drawn in four different types of tubes (serum separator tubes, fast-clotting serum tubes, lithium-heparin tubes and sodium fluoride, EDTA and a citrate buffer (NaF-EDTA-citrate) tubes, all from Greiner Bio-One). Lithium-heparin tubes were placed in an ice-water slurry until centrifugation in accordance with international recommendations and centrifuged within 10 min. After centrifugation, glucose was measured in all tubes (timepoint T0) and after 24, 48, 72, 96 and 120 h of storage at 20-22 °C. NaF-EDTA-citrate plasma showed significant overestimation of glucose concentration by 4.7% compared to lithium-heparin plasma; fast-clotting serum showed glucose concentrations clinically equivalent to lithium-heparin plasma. In fast-clotting serum tubes, mean bias between glucose concentration after 24, 48, 72, 96 and 120 h and T0 was less than 2.4%. All individual differences compared to T0 were less than 6.5%. The results fulfill the acceptance criteria for sample stability based on biological variation. Fast-clotting serum tubes can be an alternative for the measurement of glucose in diagnosis and management of GDM and diabetes mellitus, especially when prolonged transportation is necessary.


Assuntos
Diabetes Gestacional , Heparina , Gravidez , Feminino , Humanos , Glucose , Ácido Cítrico/farmacologia , Ácido Edético , Lítio , Glicemia , Temperatura , Gelo , Citratos , Coleta de Amostras Sanguíneas/métodos , Fluoreto de Sódio/farmacologia , Diabetes Gestacional/diagnóstico , Centrifugação
5.
Methods Mol Biol ; 2761: 39-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38427227

RESUMO

Extracellular vesicles (EVs) are small lipid bilayer vesicles released by cells to facilitate cell-to-cell communication. To study their biological roles and functions, they need to be isolated and purified, which can be achieved through a variety of methods. Here, we describe different methods for isolating and purifying EVs, with a focus on calculating the required g-force and centrifugation time with different centrifuges and rotors. We have compiled key formulas and tested predicted parameters for EV acquisitions to provide a comprehensive guide for EV isolation.


Assuntos
Vesículas Extracelulares , Centrifugação , Centrifugação com Gradiente de Concentração/métodos
6.
J Equine Vet Sci ; 135: 105046, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38503353

RESUMO

The objectives of this study were to evaluate the effect of a short, cooled storage before cryopreservation on sperm progressive motility (PM) and compare the effect of different centrifugation methods on post-thaw PM of stored samples. Semen was diluted in chilling extender and aliquoted in 6 protocols: i) Standard centrifugation (SC) followed by freezing; ii) Single Layer Centrifugation (SLC) followed by freezing; iii) Storage for 8 h/5 °C before SC; iv) Storage for 8 h/5 °C before SLC; v) Storage for 8 h/15 °C before SC; and vi) Storage for 8 h/15 °C before SLC. PM was assessed before centrifugation, after centrifugation, and post-thawing. Stallions were classified as "good freezers" (GF) or "bad freezers" (BF). The PM in samples immediately frozen was greater than in the stored ones (71.98 ± 14.2, 52.91 ± 17.8, 53.93 ± 18.9 for no storage, 5 ºC storage and 15 ºC storage, respectively) (P˂ 0.0001). There was an effect of storage condition (p ˂ 0.0001), centrifugation method (p ˂ 0.0001), and freezability (P=0.0016), with an interaction between them (P= 0.0004), on PM after centrifugation. Post-thaw PM was greater in samples treated by SLC than in samples processed by SC, for all storage conditions (p ˂ 0.05). All BF stallions 'showed post-thaw PM ˂ 30 % when samples were previously stored. Storage at 5 ºC or 15º C for 8 h maintains an appropriate quality in GF stallions. Applying a sperm selection technique as SLC is suggested to improve post-thaw motility, allowing GF straws to be frozen after storage, although BF semen should be prepared by SLC immediately after collection.


Assuntos
Preservação do Sêmen , Sêmen , Cavalos , Masculino , Animais , Preservação do Sêmen/veterinária , Preservação do Sêmen/métodos , Espermatozoides , Criopreservação/veterinária , Criopreservação/métodos , Centrifugação/veterinária , Centrifugação/métodos
7.
Aerosp Med Hum Perform ; 95(3): 158-164, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38356127

RESUMO

INTRODUCTION: Real-time cardiovascular imaging during hypergravity exposure has been historically limited by technological and physical challenges. Previous efforts at sonographic hypergravity imaging have used fixed ultrasound probes; the use of hand-held ultrasound, particularly performed by minimally trained laypersons, has been less explored. Here we will discuss handheld sonography to self-visualize carotid vascular and cardiac changes during hypergravity.METHODS: Three subjects with variable ultrasound experience ranging from no familiarity to extensive clinical experience used handheld ultrasound at rest and under stepwise +Gz hypergravity exposures (maximum +3.5 Gz) to visualize carotid vascular changes. Subxiphoid cardiac ultrasound was obtained by the most experienced subject. Subjects had variable prior hypergravity experience; all were trained in anti-G straining techniques. Sonographically inexperienced subjects underwent a brief (< 5 min) familiarization with the ultrasound probe, user interface, and desirable viewing window immediately prior to centrifugation; real-time coaching was provided. Ultrasound images were correlated to self-reported symptoms and hemodynamic data.RESULTS: Handheld ultrasound performed as desired; all subjects were successful at obtaining ultrasound images with adequate capture of windows of interest. Subxiphoid imaging efforts were limited by probe overheating and associated with variable quality of imaging due to probe displacement from straining techniques; the subject noted transient, mild discomfort and ecchymosis after imaging in the subxiphoid region.DISCUSSION: Even individuals with minimal or no ultrasound experience successfully obtained usable images under centrifuge conditions. While there were some limitations, this technical demonstration provides initial validation of handheld sonography as an available tool for real-time cardiovascular imaging in a hypergravity environment.Blue RS, Ong KM. Handheld sonographic cardiovascular imaging under hypergravity conditions. Aerosp Med Hum Perform. 2024; 95(3):158-164.


Assuntos
Medicina Aeroespacial , Hipergravidade , Humanos , Centrifugação , Hemodinâmica , Ultrassonografia
8.
STAR Protoc ; 5(1): 102914, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38386549

RESUMO

Extracellular vesicles (EVs) are secreted by cells under various conditions and can contribute to the disease progression in tissues. Here, we present a protocol to separate small and large EVs from mouse hearts and cardiac tissues collected from patients. We describe steps for utilizing enzymatic digestion for release of EVs from interstitial space followed by differential centrifugation and immunoaffinity purification. The isolated EVs can be used for various experiments to gain insight into their in vivo functions. For complete details on the use and execution of this protocol, please refer to Liang et al. (2023).1.


Assuntos
Vesículas Extracelulares , Humanos , Camundongos , Animais , Coração , Centrifugação
9.
Int J Biol Macromol ; 262(Pt 2): 130170, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360225

RESUMO

The soybean glycinin (11S)-chitosan (CS) complex gels with various textural properties were successfully constructed. The process involved the initial formation of 11S-CS coacervates through electrostatic interactions, followed by a heating treatment to obtain the final complex gels. The impacts of pH, heating temperature, and centrifugation on 11S-CS complex gel properties were investigated. The results indicated that the pore arrangement of the gel formed at pH 7.3 was more tightly and uniformly packed than those formed at pH 6.8 and 7.8. Centrifugation facilitated denser and more ordered gel structures at the three pH values, while increasing the heating temperature exhibited the opposite trend at pH 6.8 and 7.8. These structural differences were also reflected in the rheological and textural properties of the gel. The 11S-CS complex gels exhibited an elasticity-based gel property. The textural properties of gels formed at pH 6.8 were stronger compared to those formed at pH 7.3 and 7.8. However, when the 11S-CS coacervates were heated without centrifugation, the resulting gels were weak. This study emphasizes the potential of using protein/polysaccharide associative interactions during gel formation to alter the microstructure of the gel, meeting various production requirements.


Assuntos
Quitosana , Globulinas , Soja , Proteínas de Soja , Temperatura , Temperatura Alta , Géis/química , Reologia , Concentração de Íons de Hidrogênio , Centrifugação
11.
J Med Virol ; 96(2): e29385, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38318918

RESUMO

The aim of this study was to investigate the interference of lipemia on measurement of HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc, anti-HCV, HIV Ag/Ab, and anti-TP in serum by chemiluminescent microparticle immunoassay (CMIA) and compare lipemia removing performance between high-speed centrifugation and Lipoclear reagent. Mixed native serum samples (NSs) and hyperlipemia serum samples (HLS) were prepared for the investigated parameters. The levels of these parameters in NS and HLS were determined by CMIA on an Abbott ARCHITECT i2000SR immunoassay analyzer. HBsAg, anti-HBs, and anti-TP were affected with relative bias >12.5% (acceptable limit) when the level of triacylglycerol (TG) was higher than 27.12 mmol/L in HLS. Clinically unacceptable bias were observed for HBeAg and anti-HBe in HLS with TG higher than 40.52 mmol/L. However, anti-HCV and HIV Ag/Ab were not interfered in severe lipemia with TG < 52.03 mmol/L. In addition, the Lipoclear reagent did not reduce the interference of lipemia with relative bias from -62.50% to -18.02%. The high-speed centrifugation under the optimized condition of 12 000g for 10 min successfully removed the interference of lipemia with relative bias from -5.93% to 0% for HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc, and anti-TP. To conclude, high-speed centrifugation can be used for removing the interference of lipemia to measure HBsAg, anti-HBs, HBeAg, anti-HBe, anti-HBc, and anti-TP. Accordingly, a standardized sample preanalytical preparation of the patients and other screening participants as well as a specimen examination procedure for removing lipemia interference on the serological tests was recommended.


Assuntos
Síndrome de Imunodeficiência Adquirida , Hepatite B , Hepatite C , Hiperlipidemias , Sífilis , Humanos , Antígenos de Superfície da Hepatite B , Antígenos E da Hepatite B , Indicadores e Reagentes , Sífilis/diagnóstico , Vírus da Hepatite B , Anticorpos Anti-Hepatite B , Imunoensaio , Hepatite C/diagnóstico , Testes Sorológicos , Triglicerídeos , Centrifugação
12.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(2): 183-188, 2024 Feb 15.
Artigo em Chinês | MEDLINE | ID: mdl-38385231

RESUMO

Objective: To explore the best centrifuge condition for preparing rabbit leukocyte-poor platelet-rich plasma (LP-PRP) by using single centrifugation method. Methods: Sixteen healthy New Zealand rabbits, aged 3-4 months, were utilized in the investigation. A total of 15 mL anticoagulated blood was extracted from the central ear artery of each rabbit, with a repeat of the blood collection procedure after 1 and 2 months. The obtained blood specimens were individually subjected to centrifugation at a radius of 16.7 cm and speeds of 1 200, 1 300, 1 400, and 1 500 r/min (equivalent to centrifugal forces of 269× g, 315× g, 365× g, and 420× g) for durations of 2, 3, 4, and 5 minutes, resulting in a total of 16 groups. Following centrifugation, collect plasma from each group to a distance of 1.5 mL from the separation plane. The volumes, platelet enrichment coefficient, and platelet recovery rates of LP-PRP in each group, under varying centrifugation conditions, were methodically computed and subsequently compared. Results: The volume of LP-PRP obtained under all centrifugation conditions ranged from 1.8 to 7.6 mL. At a consistent centrifugal speed, an extension of centrifugation time leaded to a significant increase in the volume of LP-PRP, accompanied by a declining trend in the platelet enrichment coefficient of LP-PRP. When centrifuged for 2 minutes, the volume of LP-PRP at speeds of 1 200 and 1 300 r/min was less than 2.0 mL, while the volume of LP-PRP obtained under other conditions was more than 2.0 mL. When centrifuged for 4 and 5 minutes, the volume of LP-PRP obtained at each speed was more than 4 mL. LP-PRP with a platelet enrichment coefficient more than 2.0 could be prepared by centrifuging at 1 200 r/min for each time group and 1 300 r/min for 2 and 3 minutes, and the highest LP-PRP platelet enrichment coefficient could be obtained by centrifugation for 2 minutes at a speed of 1 200 r/min. The platelet recovery rates of LP-PRP obtained by centrifugation at 1 200 r/min for 4 and 5 minutes, as well as centrifugation at 1 400 r/min for 5 minutes, were both greater than 60%. There was no significant difference between the groups when centrifuged at 1 200 r/min for 4 and 5 minutes ( P>0.05). Conclusion: In the process of preparing rabbit LP-PRP using a single centrifugation method, collecting 15 mL of blood and centrifuging at a radius of 16.7 cm and speed of 1 200 r/min for 4 minutes can prepare LP-PRP with a volume exceeding 2.0 mL, platelet enrichment coefficient exceeding 2.0, and platelet recovery rate exceeding 60%. This centrifugal condition can achieve the optimal LP-PRP action parameters in the shortest possible time.


Assuntos
Leucócitos , Plasma Rico em Plaquetas , Coelhos , Animais , Centrifugação/métodos , Artérias
13.
Curr Protoc ; 4(2): e991, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38358026

RESUMO

Basophils represent the rarest type of granulocyte in human peripheral blood. Thus, researching basophils has historically been challenging and has often been reliant on enrichment protocols using density gradient centrifugation. This article describes a novel, fast, and cost-effective method to purify highly viable human basophils from peripheral blood through negative immunomagnetic selection, foregoing the density centrifugation step in the Basic Protocol. The technique is easy to use and consistently produces purities >96%. Furthermore, the Support Protocols describe procedures to determine basophil yield, purity, and viability, and how to investigate functional activity of the purified basophils through flow cytometry and visualize the basophils through microscopy. © 2024 The Authors. Current Protocols published by Wiley Periodicals LLC. Basic Protocol: Gradient centrifugation-independent basophil isolation Support Protocol 1: Flow cytometry staining to assess basophil yield, purity, and viability Support Protocol 2: Giemsa staining Support Protocol 3: Calcium flux analysis Support Protocol 4: Basophil activation test.


Assuntos
Basófilos , Humanos , Separação Celular/métodos , Citometria de Fluxo , Centrifugação , Centrifugação com Gradiente de Concentração
14.
Methods Mol Biol ; 2772: 115-127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38411809

RESUMO

Free-flow electrophoresis (FFE) is a technique for separation of proteins, peptides, organelles, and cells. With zone electrophoresis (ZE-FFE), organelles are separated according to surface charge. The ER is the only remaining major cellular compartment in Arabidopsis not to have been isolated using density centrifugation, immune-isolation, or any other method previously applied to purification of plant membranes. By using continuous-flow electrophoresis, ER vesicles of similar surface charge, which may have been fragmented during cell lysis, can be focused. A large portion of these vesicles are of sufficiently different surface charge that separation from the majority of Golgi and other contaminants is possible. Here we adapt an earlier ZE-FFE Golgi isolation protocol for the isolation of highly pure ER vesicles and for tracking the migration of peripheral ER vesicles. Isolating ER vesicles of homogeneous surface charge allows multi-omic analyses to be performed on the ER. This facilitates investigations into structure-function relationships within the ER.


Assuntos
Arabidopsis , Retículo Endoplasmático , Morte Celular , Centrifugação , Eletroforese
15.
Methods Mol Biol ; 2772: 383-389, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38411830

RESUMO

In this book chapter, we present a method for microsome isolation from the hypocotyl tissue of dark-grown Arabidopsis thaliana. Microsomes are heterogeneous, vesicle-like membranes, which are, not exclusively, derived but enriched with membranes of the endoplasmic reticulum (ER). Here, we describe the experimental setup, including sample preparation, homogenization, differential centrifugation steps, and quality control measures after microsome isolation.


Assuntos
Arabidopsis , Hipocótilo , Microssomos , Retículo Endoplasmático , Centrifugação
16.
Food Chem ; 446: 138807, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38422640

RESUMO

Satisfactory separation of milk-derived extracellular vesicles (MEVs) is important for the downstream analysis of the functions and properties of MEVs. However, the presence of abundant proteins in milk hindered the separation of MEVs. In this study, three pretreatment methods, including sodium citrate (SC), acetic acid (AA), and high-speed centrifugation, were adopted to separate MEVs from goat milk while minimizing the impact of protein. The MEVs were then characterized by nanoparticle tracking, transmission electron microscopy and western blotting experiments. The results indicated that pretreatments with AA and SC greatly decreased the impact of casein, but AA pretreatment damaged the surface structure of MEVs. Additionally, the differential centrifugation process resulted in a slight loss of MEVs. Overall, MEVs with small size and high purity can be obtained under 125 k × g centrifugation combined with SC pretreatment, which suggests a promising method for separation of MEVs from goat milk.


Assuntos
Vesículas Extracelulares , Leite , Animais , Leite/química , Citrato de Sódio , Centrifugação , Vesículas Extracelulares/metabolismo , Caseínas/metabolismo , Cabras/metabolismo
17.
Lab Chip ; 24(4): 913-923, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38263850

RESUMO

The significant biological and functional differences between small and large platelets suggested by recent studies could have profound implications for transfusion medicine. However, investigating the relationship between platelet size and function is challenging because separating platelets by size without affecting their properties is difficult. A standard approach is centrifugation, but it inevitably leads to premature activation and aggregation of separated platelets. This paper describes the development and validation of a microfluidic device based on controlled incremental filtration (CIF) for separating platelets by size without the cell damage and usability limitations associated with centrifugation. Platelet samples derived from whole blood were used to evaluate the dependence of the CIF device separation performance on design parameters and flow rate, and to compare the properties of PLT fractions generated by the CIF device with those produced using a centrifugation protocol in a split-sample study. This was accomplished by quantifying the platelet size distribution, mean platelet volume (MPV), platelet-large cell ratio (P-LCR) and platelet activation before and after processing for all input and output samples. The 'large platelet' fractions produced by the CIF device and the centrifugation protocol were essentially equivalent (no significant difference in MPV and P-LCR). Platelets in the 'small platelet' fraction produced by the CIF device were significantly smaller than those produced by centrifugation (lower MPV and P-LCR). This was because the CIF 'small platelet' fraction was contaminated by much fewer large platelets (∼2-times lower recovery of >12 fL platelets) and retained the smallest platelets that were discarded by the centrifugation protocol. There was no significant difference in platelet activation between the two methods. However, centrifugation required a substantial amount of additional anticoagulant to prevent platelet aggregation during pelleting. Unlike centrifugation, the CIF device offered continuous, flow-through, single-step processing that did not cause platelet aggregation. Such a capability has the potential to accelerate the basic studies of the relationship between platelet size and function, and ultimately improve transfusion practice, particularly in the pediatric setting, where the need for low-volume, high-quality platelet transfusions is most urgent.


Assuntos
Plaquetas , Agregação Plaquetária , Humanos , Criança , Centrifugação , Filtração , Dispositivos Lab-On-A-Chip , Separação Celular/métodos
18.
Life Sci Space Res (Amst) ; 40: 19-20, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38245344

RESUMO

Rapid deconditioning and comprehensive deleterious physiological changes that result in bedrest affect every system, function and cell of the body. It was assumed that the inherent inactivity was the cause of the problem, and that exercise would restore good health (Vernikos, 2018). However, numerous studies exploring different types and bouts of exercise once a day during bedrest produced only partial benefits. The usual frequent signal to the vestibular system of the inner ear and the brain, of changing posture, such as standing up regularly during a normal day's activities, goes silent in the microgravity of space, in bedrest or when sitting continuously. Making frequent use of gravity stimulation by standing up often throughout the day accelerates rehabilitation. Though centrifugation has been used in the aerospace field, this is a new approach in clinical practice. Postural change apart, another type of Gravity Therapy is the passive riding of a human centrifuge with or without activity. Accelerated rehabilitation through Gravity Therapy can get patients up and about, back to health sooner, in addition to cutting practical and emotional costs of rehabilitation dramatically. KEY POINT: Other than getting a good night's sleep, spending too much time in bed is bad for your health.


Assuntos
Ausência de Peso , Humanos , Centrifugação , Postura , Repouso em Cama , Exercício Físico/fisiologia
19.
Anal Chim Acta ; 1287: 342033, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38182334

RESUMO

The abuse of antibiotics has become a global public safety issue, leading to the development of antimicrobial resistance (AMR). The development of antimicrobial susceptibility testing (AST) is crucial in reducing the growth of AMR. However, traditional AST methods are time-consuming (e.g., 24-72 h), labor-intensive, and costly. Here, we propose a controlled-diffusion centrifugal microfluidic platform (CCM) for rapid AST to obtain highly precise minimum inhibitory concentration (MIC) values. Antibiotic concentration gradients are generated by controlled moving and diffusing of antibiotic and buffer solution along the main microchannel within 3 min. The solution and bacterial suspension are then injected into the outermost reaction chamber by simple centrifugation. The CCM successfully determined the MIC for three commonly used antibiotics in clinical settings within 4-9 h. To further enhance practicality, reduce costs, and meet point-of-care testing demands, we have developed an integrated mobile detection platform for automated MIC value acquisition. The proposed CCM is a simple, low-cost, and portable method for rapid AST with broad clinical and in vitro applications.


Assuntos
Antibacterianos , Microfluídica , Antibacterianos/farmacologia , Centrifugação , Difusão , Testes de Sensibilidade Microbiana
20.
Theriogenology ; 216: 111-117, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38171197

RESUMO

The presence of bacteria poses a significant challenge to the quality of stallion semen used in artificial insemination. The bacterial content of insemination doses arises from various sources, such as the healthy stallion, environment, and collection equipment, and is implicated in fertility problems as well as reduced sperm quality during storage. The conventional approach of adding antibiotics to semen extenders raises concerns about antimicrobial resistance and potential negative effects on sperm characteristics, and may not be effective in inhibiting all bacteria. The objective of this study was to determine whether an innovative alternative to antibiotic usage - centrifugation through a single layer of a low density colloid (SLC) - could reduce the bacterial load in stallion semen, and to compare sperm characteristics in samples arising from this procedure, or simple extension of the ejaculate in semen extender, or from sperm washing, i.e. adding extender and then centrifuging the sample to allow the removal of most of the seminal plasma and extender. Eighteen semen samples were collected from six stallions. The semen samples were split and extended prior to washing or SLC, or received no further treatment other than extension. After preparation aliquots from each type of sample were sent for bacteriological examination; the remaining samples were stored for up to 72 h, with daily checks on sperm quality. The low density colloid SLC outperformed sperm washing or extension for bacterial reduction, effectively removing several bacterial species. The bacterial load in the samples was as follows: extended semen, 16 ± 6.7 × 105; washed, 5.8 ± 2.0 × 105; SLC, 2.3 ± 0.88 × 105, p < 0.0001. In addition, SLC completely removed some bacterial species, such as Staphylococcus xylosus. Although there is no selection for robust spermatozoa with the low density colloid, sperm motility, membrane integrity, and DNA fragmentation were not different to washed sperm samples. These findings suggest that SLC with a low density colloid offers a promising method for reducing bacterial contamination in stallion semen without resorting to antibiotics.


Assuntos
Preservação do Sêmen , Sêmen , Masculino , Cavalos , Animais , Sêmen/microbiologia , Carga Bacteriana/veterinária , Motilidade dos Espermatozoides , Espermatozoides , Centrifugação/veterinária , Centrifugação/métodos , Preservação do Sêmen/veterinária , Preservação do Sêmen/métodos , Coloides/farmacologia , Bactérias , Antibacterianos/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...